Custom Online UPS / 3 Phase UPS Low Frequency For Network Or Highway Lighting
Quick details:
Name: three inout and three output power frequency online UPS of HP
series 10KVA~400KVA
Brand: EVADA
Phase: three Phase
Description:
Online three input and three output power frequency UPS of HP series, whose unit capacity from 10KVA to 400KVA, is high performance sine wave uninterruptible power systems,which was designed for the key applications such as data processing center , the host system , manufacturing and telecommunications equipment, medical equipment. Its high availability and high reliability provide important protection for large key application systems. The series of UPS applied double conversion pure online IGBT technology and high-speed DSP digital processor and ensure the sine wave output of stable voltage and frequency.
Online three input and three output power frequency UPS of HP series applied advanced digital parallel controlled technology, can accommodate up to 8 machines running, and can provide clients options, such as harmonic suppression filters, isolation transformers and SNMP adapter and others.
Applications:
Highway lighting, billing, small and medium-scale network system room, billing centers, calling centers, business services groups, industrial process control applications, small and medium-scale office automation, computer equipments, precision equipments, medical equipments, etc.
Specifications:
model | HP 1000 | HP 1500 | HP20 00 | HP30 00 | HP 4000 | HP60 00 | HP 8000 | HP 10000 | HP 12000 | HP 16000 | HP20 000 | ||||
capability | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80 KVA | 100 KVA | 120 KVA | 160 KVA | 200 KVA | ||||
system | |||||||||||||||
Power factor of input COSΦ: | 100~70% | ||||||||||||||
Overall efficiency | 92~94%(load 100%) | ||||||||||||||
Remote signal | Three contact signals (low power, battery discharge,bypass/fault); output12Vdc 80mA | ||||||||||||||
Remote control | EPO and bypass | ||||||||||||||
Computer monitoring port | RS232 | ||||||||||||||
Operating temperature | 0±40℃ | ||||||||||||||
Maximum relative humidity | 95%(Non-condensing) | ||||||||||||||
cooling | Smart wind forced ventilation(Fan speed varies with load)) | ||||||||||||||
Safety standards | Safety standards:GB4943; Electromagnetic compatibility: GB7260.2,GB/T 17626.2~5 | ||||||||||||||
Size W*D*H(mm) | 555× 720×1200 | 800× 740×1400 | 1200× 740×1400 | 1420 ×860×1600 | |||||||||||
weight (without battery)Kg | 200 | 220 | 260 | 300 | 360 | 480 | 550 | 900 | 1020 | 1220 | 1550 | ||||
Rectified input (standard UPS) | |||||||||||||||
Rated voltage | 380V 3 phase | ||||||||||||||
Voltage Range | ±20% | ||||||||||||||
rated frequency | 50/60Hz Automatically identify | ||||||||||||||
Frequency Range | 45~65 | ||||||||||||||
Maximum input power(A) | 18 | 28 | 37 | 55 | 72 | 103 | 130 | 175 | 220 | 280 | 350 | ||||
battery | |||||||||||||||
Rated voltage | 384VDC | 432VDC | 480VDC | ||||||||||||
Charge current settings | 0.1A×C10 | ||||||||||||||
Inverter output | |||||||||||||||
Inverter output(V) | 380(3 phase +N) | ||||||||||||||
Rated Current(A) | 14 | 22 | 29 | 43 | 58 | 87 | 115 | 148 | 186 | 235 | 296 | ||||
Phase voltage settings | 200~244V(Control Pane) | ||||||||||||||
Peak (Lpeak/Lrms) | 3:01 | ||||||||||||||
waveform | Sine wave | ||||||||||||||
The distortion of Linear load voltage | <2% | ||||||||||||||
The distortion of nonlinear load voltage waveform | <5% | ||||||||||||||
Stability of steady-state voltage | ±1% | ||||||||||||||
Response of Transient voltage | ±5% in 10ms | ||||||||||||||
overload | 600’/10’/1’(110/125/150% rated current) | ||||||||||||||
Efficiency of inverter | 94%(load 100%) | 96%(load 100%) | |||||||||||||
bypass | |||||||||||||||
Rated voltage(V) | 380(3 phase +N) | ||||||||||||||
Range of input voltage | ±15%(can adjust from control pane ±10%,±25%) | ||||||||||||||
rated frequency(Hz) | 50/60 | ||||||||||||||
range of frequency | ±2%(can adjust from control pane ±5%) | ||||||||||||||
Conversion time of inverter/bypass | <1ms | ||||||||||||||
overload capability | 10’/1’/18”(150/175/200% rated current) |
model | HP25000 | HP30000 | HP35000 | HP40000 | ||||||
capability | 250 KVA | 300 KVA | 350 KVA | 400 KVA | ||||||
system | ||||||||||
Power factor of output COSΦ: | 100~70% | |||||||||
Overall efficiency | 94%(load100%) | |||||||||
Remote signal | Three contact signals (low power, battery discharge,bypass/fault);output12Vdc 80mA | |||||||||
Remote control | EPO and bypass | |||||||||
Computer monitoring port | RS232 | |||||||||
Operating temperature | 0±40℃ | |||||||||
Maximum relative humidity | 95%(Non-condensing) | |||||||||
cooling | Smart wind forced ventilation(Fan speed varies with load) | |||||||||
Safety standards | Safety standards:GB4943; Electromagnetic compatibility:GB7260.2, GB/T 17626.2~5 | |||||||||
Size W*D*H(mm) | 1600*800*1800 | 2200*1000*2000 | ||||||||
weight(without battery)Kg | 1950 | 2250 | 2650 | 3150 | ||||||
Rectified input(Twelve - pulse rectifier) | ||||||||||
Rated voltage | 380V 3 phase | |||||||||
Voltage Range | ±20% | |||||||||
rated frequency | 50/60Hz Automatically identify | |||||||||
range of frequency | 45~65 | |||||||||
Maximum input power(A) | 450 | 540 | 630 | 720 | ||||||
battery | ||||||||||
Rated voltage | 480VDC | 576VDC | ||||||||
Charge current setting | 0.1A×C10 | |||||||||
Inverter output | ||||||||||
rated voltage(V) | 380(3 phase +N) | |||||||||
rated current(A) | 378 | 454 | 530 | 606 | ||||||
Phase voltage settings | 200~244V(Control Panel) | |||||||||
peak (Lpeak/Lrms) | 3:1 | |||||||||
waveform | Sine wave | |||||||||
The distortion of linear load voltage | <2% | |||||||||
The distortion of nonlinear load voltage | <5% | |||||||||
Stability of steady-state voltage | ±1% | |||||||||
Response of Transient voltage | ±5% in 10ms | |||||||||
overload | 600’/10’/1’(110/125/150% rated current) | |||||||||
Efficiency of inverter | 95%(load 100%) | 96%(load 100%) | ||||||||
bypass | ||||||||||
Rated voltage(V) | 380(3 phase +N) | |||||||||
Range of input voltage | ±15%( can adjust from control panel ±10%,±25%) | |||||||||
Rated frequency(Hz) | 50/60 | |||||||||
range of frequency | ±2%(can adjust from control panel ±5%) | |||||||||
Conversion time of inverter/bypass | <1ms | |||||||||
Overload capability | 10’/1’/18”(150/175/200% rated current ) |
Competitive advantages:
1. advanced 6th IGBT technology
2. Advanced battery management
3. Comprehensive and reliable protection measures against all type of power problems
4. Self test while start of the UPS
5. Advanced Current Control
6. Humanized information processing technology
7. Intelligent local and remote monitor capability with RS232 port
GSM International Trade Co.,Ltd.
Our company and advantages
GSM, a professional ATM whole machine and spare parts provider, has strategic partnerships with the world leading brands ---- NCR, WINCOR NIXDORF, DIEBOLD, HYOSUNG, FUJITSU. We are the biggest authorized distributor and repair service provider in China. Our after-sale repair service is strong with more than 225 ensembles of certified engineers trained by original brands, and offer services to state-owned banks all around mainland China and HongKong.
With 10 years of experiences of expertise services, GSM gained a considerable overseas market share of 8 millions USD in 2017, and is continuously growing. We have warehouses located in Guangzhou, Shenzhen and HongKong holding abundant stocks worth of 17 millions USD which ensure prompt delivery of within merely one day of domestic arrival and three days of international port arrival.
We are a direct manufacturer in possess of two factories located in Xiamen and Shenzhen, and own three venture companies in the Philippines,Vietnam and Malaysia.
Our Service
We are making every endeavour to provide customers with our best quality products with the most competitive price in the industry. Along with our professional advice and service, we are confident to comply with every customer’s expectation.
Trading service
1.Supply of ATM whole machine and spare parts in various world leading brands, NCR, Wincor Nixdorf, Diebold, Hitachi, Glory(NMD),GRG, Kingteller, Hyosung etc.
2. Manufacture of customized products, ie ATM parts and banking equipment.
Engineering Service
1. Repairing, maintaining and refurbishing service for ATM
equipment and parts.
2. ATM upgrading solution, hardware and software.
3. Technical consultation and training service.
After-sales Service
1. 24 hours in-time and comprehensive after-sales service.
2. Professional and quick online technical support and solutions.
3. Free repair for faulted or damaged product which are under warranty also not caused by human factors.
4. For those products not covered by warranty, competitive price for repair or maintain service are available.
Our Team
GSM is strong by a comprehensive team to provide world wide services.
Management Department
Fully responsible for the company's logistics management.
Research and Development Department
Fully responsible for the development of new products.
Production Department
Ensure the quality of production and delivery time.
Sales Department
Create bridge from purchaser to the access of the best products. Provide on time feedback and tracking of the products.
Technical Department
Provide technical support during production and run quality check to final products. T
After-service Department
Fully responsible for the after-service.